Can-Am Instruments Ltd. : Sales and service for laboratory and environmental equipment
Home > Products > Chemical Analyzers

Chemical Analyzers

Alkalinity w Ammonia w Chlorine w Chlorine Dioxide w Copper w Hardness
Ozone w Particle Counter w Phosphate w TOC  w UV Treatment


  HACH APA 6000 Alkalinity Analyzer

  • Completely automated analyzer auto-calibrates, set-and-forget operation frees time for other tasks
  • Very low maintenance analyzer is self-cleaning, self-calibrating, and self-priming; reduced sample volume minimizes reagent use and allows instrument to run up to 30 days in clean water applications before maintenance and reagent replenishment
  • Advanced process control two 4-20 mA outputs and two alarm relays allow quick configuration into standard PID control loop. Can be expanded up to 14 4-20 mA outputs and 14 alarm relays
  • Constant protectionfast, accurate response minimizes process excursions
  • Accurate alkalinity determinations to 500 mg/L as CaCO3
  • Readout selectable as total or phenolphthalein
  • Easy grab sample measurements without interrupting sample flow or disrupting datalogging
  • Optional sample sequencing kits allow a single instrument to monitor two separate sample streams

Specification Sheet | Manual

 






HACH APA 6000 Alkalinity Analyzer

Click to enlarge
 
  HACH APA 6000 Low Range Ammonia Analyzer

  • Minimal sample, reagent and standard consumption
  • Auto calibration, priming and cleaning
  • Grab sample capability
  • Menu-driven digital user interface
  • Datalogging of measurements for up to 30 days

Specification Sheet | Manual

 
HACH APA 6000 Low Range Ammonia Analyzer

Click to enlarge
   
  HACH CL17 Free Residual Chlorine Analyzer

  • 0 to 5 mg/L range, dual, fully-adjustable set-point alarms
  • IP62 enclosure rating, suitable for indoor installation
  • Automatic, self-testing diagnostics
  • Minimal routine maintenance required
  • Colorimetric DPD chemistry - fast, reliable, economical
  • Unattended operation up to 30 days
  • Manual or automatic feed pump control

Specification Sheet | Manual

 
CL17 Free Residual Chlorine Analyzer

Click to enlarge
   
  HACH 9187sc Chlorine Dioxide Analyzer


Chlorine Dioxide Analyzer with sc100 controller

Features: 

  • Reagentless anlaysis of chlorine dioxide - ion-selective membrane separates electrolyte from sample water
  • All-inclusive, pre-assembled panel reduces installation expense
  • Plug & play with digital controllers simplifies setup
  • Built-in flow regulation reduces need for additional accessories
  • Integral temperature sensor provides more accurate readings
  • Includes 2 years of typical maintenance parts, reduces operating costs

Specification Sheet | Manual

 
HACH 9187sc Chlorine Dioxide Analyzer

Click to enlarge
 
  HACH APA 6000 Low Range Copper Analyzer

  • For filter analysis optimization
  • Volumetric all particles pass through the sensing area
  • Supports up to 32 size channels and 8 analog inputs (turbidity, pH, etc.)
  • Operates stand-alone or as part of a networked system

Specification Sheet | Manual

 

HACH APA 6000 Low Range Copper Analyzer

Click to enlarge
 
  HACH APA 6000 Low Range Hardness Analyzer

  • Measures low-range hardness using USEPA-approved calmagite chemistry
  • Range 50 to 10,000 ug/L
  • Accurately and continuously measures up to two sample streams
  • Operates unattended for one month
  • Virtually maintenance-free
  • Makes your water softening system more efficient and less costly

Specification Sheet | Manual

 

HACH APA 6000 Low Range Hardness Analyzer

Click to enlarge
 
  HACH 9187sc Ozone Analyzer


Ozone Analyzer with sc100 controller

  • Great for readings in low conductivity water with no interferences from oxidants or pH
  • Reagentless anlaysis of ozone - ion-selective membrane separates electrolyte from sample water
  • All-inclusive, pre-assembled panel reduces installation expense
  • Plug & play with digital controllers simplifies setup
  • Built-in flow regulation reduces need for additional accessories
  • Integral temperature sensor provides more accurate readings
  • Includes 2 years of typical maintenance parts

Specification Sheet | Manual

 
HACH 9187sc Ozone Analyzer

Click to enlarge
 
  HACH 2200 PCX Particle Counter

Particle Counter, with RS485 I/O and Water Weir.
  • For filter analysis optimization
  • Volumetric all particles pass through the sensing area
  • Supports up to 32 size channels and 8 analog inputs (turbidity, pH, etc.)
  • Operates stand-alone or as part of a networked system

Specification Sheet | Manual

 
HACH 2200 PCX Particle Counter

Click to enlarge
 
  HACH PHOSPHAX sc


Phosphate Analyzer, 0.05-15mg/l PO4-P, 115V, 5m Filter Probe sc

Wide measurement range for a variety of wastewater applications.
  • Low detection limit of 0.05 mg/L
  • Fast 5 minute response time including sample preparation
  • Environmentally controlled for rugged, outdoor installations
  • Designed specifically for easy installation at the measurement point
  • Fully featured "Plug & Play" digital controller
  • Low Maintenance
    • The probe is equipped with a self-cleaning membrane
    • 3-Month supply of all consumables at the shortest cycle time (5 min)
    • Automatic cleaning and calibration every day
    • Conprehensive self-diagnostics
    • Easy access to reagents and wear parts

Specification Sheet | Manual

 





ACH PHOSPHAX sc

Click to enlarge
 
  HACH Total Organic Carbon Analyzer


astroTOC UV Turbo TOC Analyzer for Cogen Applications

Fast and accurate low level TOC analysis without interferences. Available in ranges of 0-2000 up to 0-50,000 µg/l.
  • Response time less than 5 minutes with 100% oxidation
  • Sample composition and oxidation by-products do not interfere
  • Uses proven NDIR technology with supreme accuracy at low levels
  • Advanced diagnostics and features designed for ease of use

Specification Sheet | Manual

 


HACH Total Organic Carbon Analyzer

Click to enlarge
 
  HACH Total Organic Carbon Analyzer 


astroTOC HT TOC Analyzer for Industrial Applications

Reliable high temperature TOC analysis with superior uptime and a lower cost of ownership. Available in ranges of 0-25 up to 20,000 mg/l.

  • Battery or A/C Powered.
  • Single or Multiple Bottles.
  • Highest Sample Integrity for data you can count on.
  • Simple to Understand, Efficient to Use.
  • Small and Lightweight, handling is made easy.
  • Built to last with rugged construction and a sealed controller. 

Specification Sheet | Application Notes | Manual

 


astroTOC HT TOC Analyzer for Industrial Applications

Click to enlarge
     
  HACH NITRATAX plus sc Sensor, 1 mm path length

  • UV absorption method-proven, continuous, and precise
  • Eliminates reagents, sampling, and sample conditioning
  • Self-cleaning probe
  • Life-long factory calibration
  • Full-featured "plug and play" with sc100 Digital Controller

Specification Sheet | Manual

 
NITRATAX plus sc Sensor, 1 mm path length

Click to enlarge
           
  HACH UVAS sc Sensor


Sensor, 2 mm, with sc100 Controller

Continuous UV 254 Absorbance/Transmittance measurements can be used to protect plant treatment processes from high organic loads. Analysis range of 2mm probe is 0-1500 m-1. Available: 1mm, 5mm and 50mm probes.

Applications:
  • Protection of treatment plants from industrial dischargers
  • Monitoring shock loads from internal plant processes
  • Control of activated sludge processes
  • Control methanol feed in BNR based on organic loading
  • Final effluent monitoring
  • Monitoring efficiency of UV disinfection processes

Specification Sheet | Manual

 




UVAS sc Sensor, 2 mm, with sc100 Controller